Note : Pre-order item
Model : TM188D
Features : - WBGT (Wet bulb Globe Temperature) measure heat stress in the field - Dual LCD display with the maximum reading of 9999 - Quick-response capacitance sensor - Accurate measurement for wet bulb globe temperature (WBGT), black globe temperature (TG), humidity (%RH), air temperature (TA), wet bulb (WET) and dew point (DEW) with fast response times - Max / Min and data hold - Low battery indication - LCD display with LED backlight - Manual data memory : 50 records - Viewing data records - Selectable units of °C and °F - Brass black ball in 50 mm diameter - WBGT alarm setting - Auto power off with disable function - Interface : USB PC serial interface - Datalogging capacitiy : 12000 records - Sampling interval : max 24 hours; min 1 second - In order to measure the WBGT index, you should refer to the following regulations : ISO7243 : Hot environments. Estimation of heat stress on working man. ISO 7726 : Ergonomics of the thermal environment-instruments for measuring physical quantities - Tripod threads
Specifications : (23±5°C)
Wet Bulb Globe Temperature (WBGT)
|
Unit
|
Range
|
Resolution
|
Accuracy@15~40°C
|
Indoor & Outdoor Without Sunlight
|
°C
|
0 ~ 59.0°C
|
0.1°C
|
±1.0°C
|
°F
|
32.0 ~ 138.0°F
|
0.1°F
|
±1.8°F
|
Outdoor With Sunlight
|
°C
|
0 ~ 56.0°C
|
0.1°C
|
±1.5°C
|
°F
|
32.0 ~ 132.0°F
|
0.1°F
|
±2.7°F
|
Indoor & outdoor without sunlight : WBGT = (0.7xWET) + (0.3xTG)
Outdoor with sunlight : WBGT = (0.7xWET) + (0.1xTA)
|
Air Temperature (TA)
|
Unit
|
Range
|
Resolution
|
Accuracy@15~40°C
|
°C
|
0 ~ 50.0°C
|
0.1°C
|
±0.8°C
|
°F
|
32 ~ 122.0°F
|
0.1°F
|
±1.5°F
|
Black Globe Temperature (TG)
|
Unit
|
Range
|
Resolution
|
Accuracy@15~40°C
|
°C
|
0 ~ 80.0°C
|
0.1°C
|
±0.6°C
|
°F
|
32.0 ~ 176.0°F
|
0.1°F
|
±1.1°F
|
Relative Humidity (%RH)
|
Range
|
1 ~ 99%
|
Accuracy
|
±3.0% RH (20 ~ 80%)
±5.0% RH (80%)
|
Resolution
|
0.1%
|
Dew Point Temperature (DEW)
|
Unit
|
Range
|
Resolution
|
°C
|
-35.3 ~ 48.9°C
|
0.1°C
|
°F
|
-31.5 ~ 120.1°F
|
0.1°F
|
The value is calculated from the RH and Air Temp
|
Wet Bulb Temperature (WET)
|
Unit
|
Range
|
Resolution
|
°C
|
-21.6 ~ 50.0°C
|
0.1°C
|
°F
|
-6.9 ~ 122.0°F
|
0.1°F
|
The value is calculated from the RH and Air Temp
|
Note : All the above descriptions are subject to change without notice
Country of origin : Taiwan.
Warranty : 1 year against manufacturing defects. Remarks : For warranty claim :- 1) There is NO one to one exchange. 2) Unit need to sent back to manufacturer for rectification & repair.
Delivery : 3 to 5 days (in-stock unit) else 2 to 4 weeks (pre-order unit) subject to factory confirmation
Free Shipping Within Malaysia
Tel : +6012 728 1063
Email : enquiry@giitechnology.com |